Electrical Design Engineer

Posted by Larsen & Toubro on its own career page, for Chennai.

Live: we never show roles older than 5 days, and we alert you only to roles under 24 hours old.

About this role

Company
Larsen & Toubro
Where
Chennai Head Qrs., Tamil Nadu, India
Field
Engineering and construction
Level
Senior
Experience asked
4 to 8 years
Kind of work
Employee
Posted

In short

Designs pumping station, switchyard and transmission line electrical systems, producing single line diagrams, protection schemes and equipment specifications.

How to apply

  1. Read the description below and check what the role asks for.
  2. Apply on the company's own career page with the button above.
  3. Set up NinjaApply once with your resume to hear about roles like this in their first day.

Apply early: the first hour after a role opens is the best time, and the longer you wait, the more your chances can fall.

The job description

From Larsen & Toubro's own posting, as it was when we read it.

Electrical Design Engineer

(Specialization: Pumping Stations, Switchyards, & Transmission Lines)

Position Summary

The Senior Electrical Design Engineer is responsible for executing the complete conceptual, basic, and detailed electricalengineering for large-scale water infrastructure and power delivery systems. This role demands specialized technical expertisein designing high-capacity pumping station electrical systems, outdoor switchyards, and high-voltage transmission lineinterconnections. The engineer will ensure seamless power flow, robust grid connectivity, and strict compliance with statutoryand utility requirements.

Key Responsibilities & Technical Accountabilities

  • Pumping Station Infrastructure Engineering
  • Design High Voltage (HV), Medium Voltage (MV), and Low Voltage (LV) distribution networks to support high-capacity verticalturbine, horizontal split-case, and submersible pumping machinery.
  • Size and select large inductive motor drivers, Motor Control Centers (MCCs), Variable Frequency Drives (VFDs) and SoftStarters.
  • Develop comprehensive electrical layouts including Single Line Diagrams (SLDs), schematic diagrams, control interlocks, andprotection logic for pump operation.
  • Coordinate with process and mechanical teams to establish control philosophies for surge protection, motorized valveoperations, and PLC/SCADA automated pumping sequences.
  • Switchyard & Substation Design (up to 132/220kV)
  • Engineer complete outdoor air-insulated (AIS) or gas-insulated (GIS) switchyard layouts, including equipment structures,gantry towers, and transformer bays.
  • Sizing and technical specification of critical high-voltage assets: Power Transformers, Circuit Breakers (SF6/Vacuum), CurrentTransformers (CTs), Potential Transformers (PTs), Lightning Arresters, and Isolators.
  • Execute advanced switchyard calculation design arrays: shielding/lightning protection layouts, grounding/earthing grids (usingIEEE 80 standards), and direct busbar sizing calculations.
  • Design control and relay panels (CRPs), implementing comprehensive protection schemes (differential, distance, overcurrent,and earth fault protection).
  • Transmission Line Engineering
  • Perform mechanical and electrical design for high-voltage overhead transmission lines and underground

cabling networks connecting switchyards to the utility grid.

  • Select and optimize conductor specifications (e.g., ACSR, AAAC configurations) based on ampacity, corona

Job Description

loss, sag-tension profiles, and short-circuit parameters.

  • Conduct voltage drop calculations for long-distance transmission runs, optimizing tapping points and subdistribution

topologies to guarantee grid code compliance.

  • Coordinate route alignment surveys, tower spotting layouts, clearance compliance (ground, structural, and

environmental), and technical right-of-way (ROW) frameworks.

  • System Simulations & Interconnection Studies
  • Execute comprehensive electrical network simulations using ETAP or similar software: load flow analysis,

short-circuit containment studies, relay coordination, and dynamic motor acceleration profiling.

  • Draft exhaustive technical specifications, procurement-ready datasheets, and Purchase Requisitions for

heavy equipment procurement.

  • Manage Technical Bid Evaluations for vendor offerings and supervise Original Equipment Manufacturer

(OEM) Factory Acceptance Testing (FAT).

Technical Qualifications & Requirements

  • Education: Bachelor's or Master's Degree (B.E./B.Tech/M.Tech) in Electrical Engineering from an

accredited institution.

  • Experience: Dedicated design engineering experience with a demonstrable portfolio featuring industrial

pumping stations, utility switchyards, and power evacuation transmission lines.

  • Software Proficiency: Expert-level diagnostic mastery of ETAP (or equivalent network simulation

platforms), AutoCAD, and PLS-CADD (preferred for transmission lines).

  • Standards Knowledge: In-depth structural understanding of international and national codes: IEEE, IEC,

NEC, CIGRE, and regional State Electricity Board/Utility transmission regulations.

Key Performance Indicators (KPIs)

  • Design Rigor: Minimize construction-phase engineering modifications and site variations through precise

sizing and clear interfaces.

  • Schedule Adherence: Timely delivery of approved documents/drawings for procurement and construction

against major project milestones.

  • Utility Acceptance: Smooth, comment-free clearance of switchyard protection schemes and transmission

line alignments from regional power utilities and statutory electrical inspectorates.

Experience: 4 to 8 years

Employment: Permanent